LEARN MORE ABOUT...
  New Products
  Keep up-to-date on product introductions and software version releases.
 
 
Velocity 3.0  
The latest version of Hirsch’s award-winning software.

 
divider  
  Interoperability  
   Hirsch leads the industry in enabling security to work with other systems.
divider  




  

 Velocity 2.6 Release Notes

 

  Velocity 2.6 (Build 2.6.0.18)

This CD contains Velocity 2.6.   This CD will not update previous versions of Velocity to version 2.6.  If you need an update CD please contact your dealer or Hirsch Electronics.

Release Prerequisites:

Product Packaging

  • The package for a new Velocity installation is shipped as a 3 CD set.  One CD contains the Velocity product and the second CD contains Drivers and Service packs to help make your installation go smoothly and the third CD contains Tutorials.
  • To order a CD Set for new Velocity customers you will need to use part number VEL.
  • To order a CD Set for existing Velocity customers running previous versions (1.0.9.60, 2.5.0.28, 2.5.0.35, 2.5.0.37) who wish to update to Velocity 2.6 you will need to use part number VEL-UPD26 and possibly VEL-UPD25 depending on your current version.  Please refer to the Velocity 2.6 Upgrade Release Notes document for more specifics.

Velocity 2.6 Operating System and Service Pack Requirements

·         The Velocity Installer has been updated to allow installation on Windows 2000 and Windows XP for Client and Standalone Workstation configurations and Windows Server 2003 when running SQL Server 2000.

·         Windows 2000 Server and Windows Server 2003 (requires SQL Server 2000) are the only operating systems that support client connections.

·         For Windows 2000 Professional and Server configurations Service Pack 3 or above for Windows 2000 is now required.  The current Microsoft Service Pack can be found on the Velocity Utilities CD or at www.microsoft.com.

·         Service Pack 4 for Microsoft SQL Server 7.0/MSDE 1.0 is automatically installed when required.  MSDE installation is not supported on Windows Server 2003. 

·         The following are the supported Operating System and Database Configurations for Velocity 2.6 Standalone Workstations and Servers:

Velocity Configuration

MSDE

SQL Server 7

SQL Server 2000

Single-User System running  W2K Pro or XP Pro

þ
Included

þ
Optional

(Desktop Edition Only)

þ
Optional

(Personal Edition Only)

Windows Server 2000

þ
Included

þ
Optional

þ
Optional

Windows Server 2003

ý
Not Supported

ý
Not Supported

þ
Required-Not Included

Velocity 2.6 CCM Requirements

The Velocity 2.6 release requires that you be running DIGI*TRAC CCM Firmware 7.2.03 or higher (the currently shipping CCM version is 7.2.07).  Failure to perform this update will result in unpredictable product behavior.  The new CCM Firmware file can be found in the CCM directory in your Velocity directory. It is not necessary to install 2.5 before performing the CCM 7.2.03 or higher update.  Therefore customers can update their current CCM to 7.2.03 or higher while running Velocity 2.0b.  The most recent firmware can be found in the \Velocity\CCM directory on the Velocity 2.6 Software CD.

Installation Notes

  • Confirm your current version of CCM firmware to determine if a firmware download is required. Velocity 2.6 requires versions 7.2.03 or higher. The currently shipping version at the time this document was created is 7.2.07.
  • During the MSDE installation step, if you are installing Velocity on a Windows 2000 Server on a Windows Server 2003 domain (only if you are not installing on full SQL Server 2000) you may receive the following message:

The password does not meet the password policy requirements. Check the minimum password length, password complexity and password history requirements.

If you click the OK button the system will continue to install. This is caused by Microsoft BUG #: 56075. The Velocity installer corrects this defect when it installs the SQL Server 7 Service Pack 4. See Microsoft Knowledge Base Article - 249294 for more details.

  • Before installing Velocity, you must be logged into the Server with an "account" that has Administrator rights. An "account" is the Name and Password assignment in Windows 2000 (in Control Panel under Users for Windows 2000 Professional for Velocity Single User installation or in Active Directory Users and Computers under Start/Programs/Administrative Tools/ for Windows 2000 Server Velocity Server installation). If you attempt to install without such rights, the Installer will generate an error and terminate. 
  • When installing a workstation on a domain the installing user will not be placed into Velocity users group. The Velocity installer cannot determine where the credential came from in Windows 2000 Pro. It always assumes it came from the local directory.

What's new in Velocity Version 2.6

  • Digital Video Recorder (DVR) Interoperability

Velocity 2.6 integrates Access Control and Intrusion Detection with Digital Video Recorder Technology.  With Velocity 2.6, any Velocity alarm or event can be used to trigger the DVR to record the event and then view the recorded video within the Velocity Alarm Viewer.  In addition, unlike the CCTV viewer you can view live video from the DVR without the need to have a video card on your PC. Only the American Dynamics (formerly Sensormatic) Intellex DV16000 and DV8000 series is supported in Velocity 2.6.
 

    • Velocity Video Explorer - Lets you view multiple cameras from multiple DVRs in a single window. Video Explorer provides a quick view of up to sixteen preset cameras on one screen. These cameras can be a mix of cameras from one or more DVR units.
    • Use Velocity Alarms and Events to trigger Video Recording
    • View Recorded Video directly from within the Velocity Alarm Viewer
    • Get and View Video Alarms generated by the DVR within Velocity
    • View Multiple DVR Cameras simultaneously on the same screen
    • The Event History Viewer enables a qualified Velocity operator to track and report events that are specific to the DVR subsystem. The DVR Event History Viewer looks and feels like the Velocity Report Manager. In fact, it shares many features with the Report Manager except that it is dedicated to DVR history logs. These logs include:
      • Active Alarms by Date
      • Active Alarms by Date with Comments
      • Alarm Log by Date
      • Alarm Log by Date with Comments
      • All Events Log by Category
      • All Events Log by Date
    • Link DVR Cameras to doors in MyVelocity
    • Drag, drop and view DVR Cameras and DVR Recorders on Graphics
    • Export Video from a DVR and store it on the Velocity PC and then transfer the Video to other media like CD-R and CD-RW
    • Fully integrated using the American Dynamics Software Developers Kit
    • TCP/IP LAN and WAN support to access DVRs anywhere on the network - even across the internet
  • MyVelocity

My Velocity is a simplified, user-friendly view of Velocity for those operators who only need to see security tasks that are relevant to their jobs and communicate with their coworkers quickly and efficiently.

Features included in this MyVelocity are:

    • Critical Functions: View and control Velocity components, including doors, DVR and CCTV cameras, relays, command sets, and reports.
    • E-Mail: Even if this Velocity system does not include a standard email system (such as Outlook Express, Outlook, or Eudora), My Velocity can provide operators a means to communicate via this Velocity network. This e-mail system can handle both voice and video mail.
    • Video Conferencing: Uses USB-compliant web-cams.

My Velocity can be customized to the specific needs of each operator, so that when that operator opens My Velocity, only those tasks permitted for the operator appear on the screen.

    • User Interface that is geared for Guards and other non-administrative personnel
    • Video and Voice over IP
    • Device and command set availability controlled by permissions
  • Master Door Group

Velocity 2.6 now supports Master Door Group.  Master Door Groups are made up of multiple standard Door Groups.  Using Master Door Groups you can better manage your controllers doors and simplify your access rules.  With Master Door Groups you can now have doors within the same controller that are defined in different door groups assigned to a single credential.  In previous versions of Velocity a credential could only be assigned a door group if it did not conflict with doors in the same controller in a different door group.

  • Switch Operator Feature

The Velocity Switch Operator feature allows the user to change operators without the need to log-off the computer.  The new users' Velocity permissions are then used during the session to control access to Velocity functionality.  This feature is important if you must allow alarms and events to be processed without interruption during a shift change.  If you intend on using this feature it is recommended that you setup generic Windows accounts to be used to log onto the network and then control Velocity permissions using Operator Groups.

  • New Enrollment Manger Features
  • The Velocity Enrollment Manager now supports 999 user defined fields across 10 new tabs.  The ability to see these new tabs is controlled by permissions in the operators groups.  The tab names can be changed using the Velocity Customization Manager.
  • The "Add New Credential", "Assign Credential", "Preview", and "Print" bottom function buttons were changed so a single click can execute them.
  • Added Pen width, color and back ground color support to Signature Capture feature.
  • Velocity Add-Ins
  • Velocity Remote Desktop

·         This add-in enables the operator to launch a terminal services session from within the Velocity shell.  There is NO data sharing between the systems.  It allows a user to access another Velocity system without having to exit their system to perform administrative functions.

  • LaunchPad
    • This add-in enables the operator to launch standard windows applications within Velocity.  This is valuable when the operator needs to run an application but cannot exit Velocity.
  • Tip for the Day
    •  This fun add-in allows you to create your own "Tips for the day."  A text file Velocitytips.txt is used to present tips in random.  You can add your own lines to the file to create reminders for Velocity users.  Refreshing operations on your organizations policies would be great application of this new feature.
  • New Graphics Enhancements
  • Added the following Velocity data elements to the Custom Badge Field feature:
    1. HostCardStamp
    2. HostCardData
    3. MatchCode
    4. HostIssueNumber
  • Enhance Badging system to support the new Enrollment Manger's Unlimited User Defined Field feature.
     

·         Added the ability to Suspend Alarm Queuing

This new feature allows the operator to temporarily suspend the Velocity Graphics Alarm Queuing feature.  The Alarm Queuing feature caused Velocity to track alarms as they come into the system.  The first alarm in causes Velocity to bring into focus that device on that graphic.  This feature is useful when you want to suspend alarm queuing to open doors, trigger a control zone or view a DVR camera and don't want the system to switch to a graphic on a new alarm.  The alarms still come into the system and are shown in the Velocity Alarm Viewer and the Graphics Alarm Queue. 

·         New Graphic Custom Links

In Velocity new custom graphics components can be created by Hirsch Engineering to deliver new functionality when appropriate.  These new components are called are called Custom Links and are added to Graphics via the Custom Link Manager component found in the Graphics Object Library window under the Special Folder.  These components can be found in the \Program Files\Hirsch Electronics\Velocity\GraphicFiles Folder.

·         AXIS™ Camera Graphics Link

This Custom Link enables the operator to launch an AXIS™ Camera from any Graphics Page.  You simply drag the AXIS Custom Link object to your graphics page and then add the IP Address to the objects properties.  When you double-click on the AXIS Custom Link Velocity will launch the viewer for that camera.

·         Quick Link

This Custom Link enables the operator to launch an HTML Page from any Graphics Page.  You simply drag the Quick Link object to your graphics page and then add the IP Address to the objects properties.  When you double-click on the Quick Link Velocity will launch the defined HTML Page.

  • Report Manager Changes

In Version 2.6, the Velocity Report Manager now uses Crystal Reports 10.0 print engine.  The change was made because reports created by customers using Crystal Reports 9.1 or higher would not run when imported into the Velocity Report Mangers.  Reports created by customers or dealers in pre-9.1 versions of Crystal Reports may have to be updated to this new version of Crystal Reports to function properly.

  • New Operator Group Permissions

Operator Group permissions have been expanded to support MyVelocity.  These new permissions control access to Door, Relays and Cameras within MyVelocity.  These permissions do not control access to these devices in other parts of Velocity.  In other words, this should not be considered as database partitioning.

  • Email Notification now supports Text Messages (for Cell Phone and Pagers that do not support HTML)

The Velocity Email Notification feature now can send message in a pure text format.  This feature is useful when the email recipient is using cell phones or pagers that do not support HTML formatted email.  The Velocity Email Notification feature continues to support HTML messages as well.

  • PAL Support for the CCTV Viewer for International Customers

The Velocity CCTV viewer has been updated to support the PAL Video format.  The NTSC video format is used by United States, Canada, Japan and Mexico.  The PAL video format is used by the other countries.

  • Increased the size of Input and Expansion Input names

The number of characters that can be used to name an Input or expansion input has been increased from 32 to 64.

  • Velocity Badging Enhancements

Velocity Badging MAGSTRIPE Encoding options has been moved to Custom Fields in Badging.  Instead of only supporting the Ultra MagiCard MAGSTRIPE format, Velocity now allows the user to defined their own encoding macros within the Custom Fields feature in Badging.  In addition, MagStripe encoding no longer requires special setting in the printer driver.  The defaults for the Printers' MagStripe encoding option can now be used.

  • Ultra MagiCard format
  • Eltron format
  • Fargo format
  • Interoperability Developers Kit (IDK)

Hirsch is very pleased to announce the creation of the Velocity Interoperability Developers Kit (IDK) in conjunction with Velocity 2.6.  The Velocity IDK enables in-house or 3rd party software developers to manipulate Velocity People and Credential information and to perform control functions as well as view and acknowledge alarms and view events. Please contact your Dealer or Hirsch Regional Manager to find out the details and pricing on the Velocity IDK.

Velocity Interoperability Developers Kit (IDK) highlights:

  • Application Programmers Interface (API) - Lets you add, change and delete People and their Credentials from a Visual Basic program.
  • XML Web Server Interface – Perform Velocity Control Functions and Alarm Acknowledgement via XML documents
  • XML Writer - Routes Velocity Alarms and Events of your choice to a TCP port as XML documents for use by an user-written or 3rd party program.

Revision Date: May 10, 2004

Copyright © 2004  Hirsch Electronics Corporation. All rights reserved.

 


Home | About UsProduct Overviews | Product Catalog | Sales | Tech Support | Training | Partners
News | Awards | Tradeshows | Gov't Prog. | Search | Contact
Copyright © 2000-2008 Hirsch Electronics Corporation. All rights reserved.