 Velocity 2.6 Update Release Notes

 

  Velocity 2.6 Update (Build 2.6.0.18)

This CD contains the Velocity 2.6 Update (Part number: VEL-UPD26).  This CD will update your Velocity 2.5 SP1a (Build 2.5.0.37) system to Velocity 2.6 (Build 2.6.0.18).  If you need a new-installation CD please contact your dealer or Hirsch Electronics and order part number VEL.

Update Prerequisites:

Product Packaging

  • The package for the Velocity 2.6 update installation is shipped as a 4 CD set.  One CD contains the Velocity product, the second CD contains Drivers and Service packs to help make your installation go smoothly, the third CD contains Tutorials and the fourth CD contains Velocity 2.6 software so that you may add new Velocity clients to your updated Velocity 2.6 server.
  • To order a CD set for new Velocity customers you will need to use part number VEL.
  • To order a CD set to update older Velocity systems (Builds 1.0.9.60, 2.5.0.28, 2.5.0.35, 2.5.0.37) to Velocity 2.5 SP1a, customers will need to contact your Hirsch Representative or Dealer and order part number VEL-UPD25.

Velocity 2.6 Operating System and Service Pack Requirements

·         The Velocity Installer has been updated to allow installation on Windows 2000 and Windows XP for Client and Standalone Workstation configurations and Windows Server 2003 when running SQL Server 2000.

·         Windows 2000 Server and Windows Server 2003 (requires SQL Server 2000) are the only operating systems that support client connections.

·         For Windows 2000 Professional and Server configurations Service Pack 3 or above for Windows 2000 is now required.  The current Microsoft Service Pack can be found on the Velocity Utilities CD or at www.microsoft.com.

·         Automatic MSDE installation is not supported on Windows Server 2003.  Window Server 2003 requires the installation of SQL Server 2000 prior to installation of Velocity 2.6.

·         Service Pack 4 for Microsoft SQL Server 7.0/MSDE 1.0 is automatically installed when required. 

·         The following are the supported Operating System and Database Configurations for Velocity 2.6 Standalone Workstations and Servers:

Velocity Configuration

MSDE

SQL Server 7

SQL Server 2000

Single-User System running  W2K Pro or XP Pro

þ
Included

þ
Optional

(Desktop Edition Only)

þ
Optional

(Personal Edition Only)

Windows Server 2000

þ
Included

þ
Optional

þ
Optional

Windows Server 2003

ý
Not Supported

ý
Not Supported

þ
Required-Not Included

Velocity 2.6 CCM Requirements

The Velocity 2.6 release requires that you be running DIGI*TRAC CCM Firmware 7.2.03 or higher (the currently shipping CCM version is 7.2.07).  Failure to perform this update will result in unpredictable product behavior.  The new CCM Firmware file can be found in the CCM directory in your Velocity directory. It is not necessary to install 2.5 before performing the CCM 7.2.03 or higher update.  Therefore customers can update their current CCM to 7.2.03 or higher while running Velocity 2.0b.  The most recent firmware can be found in the \Velocity\CCM directory on the Velocity 2.6 Software CD.

Update Velocity 2.5 SP1a System (build 2.5.0.37) to Velocity 2.6 (build 2.6.0.18)

This CD only updates a Velocity 2.5 SP1a to Velocity 2.6.  This part number contains a update CD, a CD which contains the Velocity 2.6 software to be used when installing new clients on your updated system Resources CD and the Tutorial CD .  If you wish to update a pre-2.5 SP1a system to Velocity 2.6 you will need to contact your Hirsch dealer or Hirsch regional manager and order part number VEL-UPD25.  The cost for this update is $100 USD.

The Velocity Update to 2.6 will update a Velocity 2.5 SP1a (build 2.5.0.37) system.  You must update your current system to this build or the update will not run.  Please place the Update CD in your CD Drive and choose the "Update Velocity 2.5 SP1a to 2.6" option from the menu.

  • Before updating Velocity, you must be logged into the Server with an "account" that has Administrator rights. An "account" is the Name and Password assignment in Windows 2000 (in Control Panel under Users for Windows 2000 Professional for Velocity Single User installation or in Active Directory Users and Computers under Start/Programs/Administrative Tools/ for Windows 2000 Server Velocity Server installation). If you attempt to install without such rights, the Installer will generate an error and terminate. 

Suggested Update Steps:

·         Backup your Velocity 2.5 SP1a (2.5.0.37) database using the Velocity SQL Manager or Microsoft Enterprise Manager if running SQL Server 7 or 2000.

·         Verify that all Controllers are running CCM 7.2.03 or higher controller firmware

·         Stop all Velocity services using the Velocity Service Control Manager found on your system tray.

·         Exit the Velocity Service Control Manager.

·         Do not stop the SQL services using the MS SQL Server Service Manager found on your system tray.  The Velocity Update program needs this service running for the update process to complete successfully.

·         Start the update by inserting the Velocity Update CD in the CD drive and click the Update Velocity 2.5 SP1a option.

Updating Pre-2.5 SP1a Versions of Velocity

Update Velocity 2.0b (build 1.0.9.60) to Velocity 2.5 SP1a (build 2.5.0.37)

The Velocity Update to 2.5 (build 2.5.0.28) contained on the update CD will only update a Velocity 2.0b (build 1.0.9.60) system.  Update CDs can be identified 2 ways. First the serial number on the CD will begin with VEL-UPD25 and second the CD case will have a serial number label that also begins with VEL-UPD25. If you are currently running Velocity 2.0 (build 1.0.9.43) you must first update to Velocity 2.0a (build 1.0.9.45) before attempting to run the Velocity 2.0b update.  If you are currently running Velocity 1.0 you will need to contact your Hirsch dealer for the 2.0a update CD.

Very Important Information: The Velocity Version 2.5 update will update a Velocity 2.0b system to Velocity 2.5. However due to the redesign of the Velocity Graphics and Badging system in 2.5 graphics and templates created in previous versions of Velocity cannot be updated.  You will need to recreate all graphics and badge templates using the new Velocity 2.5 Graphics and Badging system. To assist you in this process a Migration Wizard has been included that will re-assign badge templates to new badge templates.  Refer to the Velocity Installation Guide for the exact procedure for upgrading to Velocity 2.5.

Suggested Update Steps:

·         Backup your Velocity 2.0b (1.9.0.60) database using the Velocity SQL Manager.

·         Update all Controllers to CCM 7.2.3 or higher controller firmware
Place the Velocity 2.5 Update CD into the CD drive.  Browse the CD and find the Velocity\CCM directory.  Copy the file ccm7_2_7_.bin to the Hirsch Electronics\Velocity\CCM folder on your hard drive. Using this file follow the CCM firmware update process as defined in your 2.0b help system.  Your 2.0b system will support the latest version of the firmware.  Once all your controllers have been updated you can proceed to step 3.

·         Stop all Velocity services using the Velocity Service Control Manager found on your system tray.

·         Exit the Velocity Service Control Manager.

·         Do not stop the SQL services using the MS SQL Server Service Manager found on your system tray.  The Velocity Update program needs this service running for the update process to complete successfully.

·         Start the update by inserting the Velocity Update CD in the CD drive and click the Update Velocity 2.0b option.

·         Create new badge templates using Velocity 2.5 Badging.

·         Run the Badge Template Migration Wizard to reassign old badge templates to the newly created ones.

·         Create new Graphics.

What's new in Velocity Version 2.6

  • Digital Video Recorder (DVR) Interoperability

Velocity 2.6 integrates Access Control and Intrusion Detection with Digital Video Recorder Technology.  With Velocity 2.6, any Velocity alarm or event can be used to trigger the DVR to record the event and then view the recorded video within the Velocity Alarm Viewer.  In addition, unlike the CCTV viewer you can view live video from the DVR without the need to have a video card on your PC. Only the American Dynamics (formerly Sensormatic) Intellex DV16000 and DV8000 series is supported in Velocity 2.6.
 

    • Velocity Video Explorer - Lets you view multiple cameras from multiple DVRs in a single window. Video Explorer provides a quick view of up to sixteen preset cameras on one screen. These cameras can be a mix of cameras from one or more DVR units.
    • Use Velocity Alarms and Events to trigger Video Recording
    • View Recorded Video directly from within the Velocity Alarm Viewer
    • Get and View Video Alarms generated by the DVR within Velocity
    • View Multiple DVR Cameras simultaneously on the same screen
    • The Event History Viewer enables a qualified Velocity operator to track and report events that are specific to the DVR subsystem. The DVR Event History Viewer looks and feels like the Velocity Report Manager. In fact, it shares many features with the Report Manager except that it is dedicated to DVR history logs. These logs include:
      • Active Alarms by Date
      • Active Alarms by Date with Comments
      • Alarm Log by Date
      • Alarm Log by Date with Comments
      • All Events Log by Category
      • All Events Log by Date
    • Link DVR Cameras to doors in MyVelocity
    • Drag, drop and view DVR Cameras and DVR Recorders on Graphics
    • Export Video from a DVR and store it on the Velocity PC and then transfer the Video to other media like CD-R and CD-RW
    • Fully integrated using the American Dynamics Software Developers Kit
    • TCP/IP LAN and WAN support to access DVRs anywhere on the network - even across the internet
  • My Velocity

My Velocity is a simplified, user-friendly view of Velocity for those operators who only need to see security tasks that are relevant to their jobs and communicate with their coworkers quickly and efficiently.

Features included in this My Velocity are:

    • Critical Functions: View and control Velocity components, including doors, DVR and CCTV cameras, relays, command sets, and reports.
    • E-Mail: Even if this Velocity system does not include a standard email system (such as Outlook Express, Outlook, or Eudora), My Velocity can provide operators a means to communicate via this Velocity network. This e-mail system can handle both voice and video mail.
    • Video Conferencing: Uses USB-compliant web-cams.

My Velocity can be customized to the specific needs of each operator, so that when that operator opens My Velocity, only those tasks permitted for the operator appear on the screen.

    • User Interface that is geared for Guards and other non-administrative personnel
    • Video and Voice over IP
    • Device and command set availability controlled by permissions
  • Master Door Group

Velocity 2.6 now supports Master Door Group.  Master Door Groups are made up of multiple standard Door Groups.  Using Master Door Groups you can better manage your controllers doors and simplify your access rules.  With Master Door Groups you can now have doors within the same controller that are defined in different door groups assigned to a single credential.  In previous versions of Velocity a credential could only be assigned a door group if it did not conflict with doors in the same controller in a different door group.

  • Switch Operator Feature

The Velocity Switch Operator feature allows the user to change operators without the need to log-off the computer.  The new users' Velocity permissions are then used during the session to control access to Velocity functionality.  This feature is important if you must allow alarms and events to be processed without interruption during a shift change.  If you intend on using this feature it is recommended that you setup generic Windows accounts to be used to log onto the network and then control Velocity permissions using Operator Groups.

  • New Enrollment Manager Features
  • The Velocity Enrollment Manager now supports 999 user defined fields across 10 new tabs.  The ability to see these new tabs is controlled by permissions in the operators groups.  The tab names can be changed using the Velocity Customization Manager.
  • The "Add New Credential", "Assign Credential", "Preview", and "Print" bottom function buttons were changed so a single click can execute them.
  • Added Pen width, color and back ground color support to Signature Capture feature.
  • Velocity Add-Ins
  • Velocity Remote Desktop

·         This add-in enables the operator to launch a terminal services session from within the Velocity shell.  There is NO data sharing between the systems.  It allows a user to access another Velocity system without having to exit their system to perform administrative functions.

  • LaunchPad
    • This add-in enables the operator to launch standard windows applications within Velocity.  This is valuable when the operator needs to run an application but cannot exit Velocity.
  • Tip for the Day
    •  This fun add-in allows you to create your own "Tips for the day."  A text file Velocitytips.txt is used to present tips in random.  You can add your own lines to the file to create reminders for Velocity users.  Refreshing operations on your organizations policies would be great application of this new feature.
  • New Graphics Enhancements
  • Added the following Velocity data elements to the Custom Badge Field feature:
    1. HostCardStamp
    2. HostCardData
    3. MatchCode
    4. HostIssueNumber
  • Enhance Badging system to support the new Enrollment Manager's Unlimited User Defined Field feature.
     

·         Added the ability to Suspend Alarm Queuing

This new feature allows the operator to temporarily suspend the Velocity Graphics Alarm Queuing feature.  The Alarm Queuing feature caused Velocity to track alarms as they come into the system.  The first alarm in causes Velocity to bring into focus that device on that graphic.  This feature is useful when you want to suspend alarm queuing to open doors, trigger a control zone or view a DVR camera and don't want the system to switch to a graphic on a new alarm.  The alarms still come into the system and are shown in the Velocity Alarm Viewer and the Graphics Alarm Queue. 

·         New Graphic Custom Links

In Velocity new custom graphics components can be created by Hirsch Engineering to deliver new functionality when appropriate.  These new components are called are called Custom Links and are added to Graphics via the Custom Link Manager component found in the Graphics Object Library window under the Special Folder.  These components can be found in the \Program Files\Hirsch Electronics\Velocity\GraphicFiles Folder.

·         AXIS™ Camera Graphics Link

This Custom Link enables the operator to launch an AXIS™ Camera from any Graphics Page.  You simply drag the AXIS Custom Link object to your graphics page and then add the IP Address to the objects properties.  When you double-click on the AXIS Custom Link Velocity will launch the viewer for that camera.

·         Quick Link

This Custom Link enables the operator to laun