CCM Release Notes 7.4.18 |
|
|
January 31,
2007 |
5 November 2007
Most customers may download the binary file through Velocity and do not need to physically replace their CCM.
Customers that may benefit from this DIGI*Trac release have one or more of these:
- Embedded LCD display (connects to MATCH2)
- Keypad programming of card credentials (stand-alone).
New in this release
- Support for new embedded LCD display. ***5 from DS47 will show LCD model information (usually type 8). Can show date and time, Access (etc.) GRANT/DENIED/OVERRIDDEN, minutes for Extended Access, and number of users inside.
- In order for the new LCD to be recognized by DIGI*TRAC with the current or recent Velocity versions, the following command must be used for each address that has the LCD: 403*(address)*65*72#. For example, in the case of address 1, 403*1*65*72 must be sent to the controller as part of its configuration. This can be included as part of a command set.
Defects fixed
- Keypad programming of cards (CMD 310, etc.) will work at readers with even or odd addresses
- Indexed Command Grant messages will display as expected on Velocity 3.0 and Velocity 3.1.
- LCD Time/date always uses a colon. It does not indicate whether Velocity is logged on to the controller.
Known limitations
- Until Velocity has native support for the new embedded LCD display, it is necessary to add a command 403*READER*65*72# for each reader that has an LCD unit.
This document covers changes to the CCM since 7.4.12